UHZ517 series magnetic level indicator for Low Temperature Frost Proof

FOB Reference Price:Get Latest Price
US $200-5,000 / Sets | 1 Set/Sets (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Shanghai, China (Mainland)
Brand Name:
FOXC
Model Number:
UHZ517C13/C13A
Nominal Pressure:
≤pn5.0MPa 300LB ANSI
Temperature:
-40℃~100℃/-196℃~100℃
Indication:
Field or with Transmitter
Type:
Column/Flap
Color:
Red &White or Black&Yellow
Mounting form:
Side mounted
SupplyAbility
SupplyAbility:
3000 Set/Sets per Week
Packaging & Delivery
Packaging Details
at requested
Port
Shanghai, China
Lead Time :
within 25 days after deposit

Technique Parameter

 

Measure Range:

150~8000mm (center distance) or on request. 

Nominal Pressure:

PN5.0 MPa Class 300LB ANSI

Working Pressure:

≤3.75Mpa  225LB

Working Temperature

UHZ517C13: -40°C ~100°C (223.15~373.15K)                                          UHZ517C13A: -196°C ~100°C (77.15~373.15K)  

Medium Density

500~2000kg/m³

Chamber(bypass tube)

Φ63×4mm

Process Connection

Factory Standard: DN25 PN5.0MPa  HG20592-97; 300LB 1" ANSI B16.5;  

 Optional std:

1/2"~ 2" ANSI B16.5;  

DN10-DN50 GB/T 9112-2000;

JB/T 79.1-94 SH3406-1996

DIN 2635;DN10-DN50;

DIN 2527;DN10-DN50

10A~50A JIS 20K FF RF;

1/2"~2" JPI 300LB RF

Chamber/Flange/ Wetted Material

304, 316, 316L, 316Ti, 321, 1.4301, 1.4435, 1.4401,

1.4571, 1.4783, 0Cr18Ni9, 1Cr18Ni9Ti, 00Cr17Ni14Mo2,

0Cr17Ni12Mo2, 0Cr18Ni2Mo2Ti

Magnetic Float

Its size depends on liquid density

Material: Titanium

Optional Items

1.  Tri-magnet level switch

2.  Quad-magnet level switch

3.  Heating Jacket

4.  Depth Vacuum heating jacket

5.  Coil type heating jacket

6.  Drain/Vent valves

7.  Transmitter(4~20mA, two/ three wire,HART)

8.  Magnetostrictive level transmitter     

 

 

 

 

UHZ-517C13  With blind flange, no drain valve
  L  Bottom drain valve
 GTri-magnet driven level switch
GH High temperature four-magnet driven level switch
     Control points(quantity of level switches)
 RLtransmitter two wire 4~20mA output
R1LB transmitter HART two-wire 4~20mA output
R2AT200 Magnetostrictive transmitter two-wire 4~20mA output HART
R3AT201 Magnetostrictive transmitter three-wire 4~20mA output HART
R4AT202 High temperature magnetostrictive transmitter output HART
R5AT203 High temperature transmitter three-wire output HART
 DExdIIBT1~T6 Explosion proof
EExiaIICT1~T6 Intrinsically safe
EFIntrinsically safe with barrierW Wide rollers board
  Removable heating jacketJ2Sleeve type heating jacket
J3Coil type heat tracing deviceJ4 Depth vacuum jacket
J5Depth vacuum insulation& compound heating jacket
  Installation height(N/A for side-side mounted level gauge
  (M)Measuring range,mm
  Medium density,kg/m3